Thứ Bảy, 22 tháng 2, 2014

Tài liệu Connectorized Cables pptx

Connectorized Cables
ADC’s connectorized cables are designed for voice and intermediate speed data applications.
Each cable assembly is equipped with either two connectors or one connector and one stub.
Specialty cables with two connectors on one end are also available. All feature 24 AWG
(0.5 mm) twisted pair cable covered with PVC jacket material.
Features:
• Unshielded, shielded, and shielded plenum Category 2, 3, and 5 cable assemblies
• 25 or 32 pair cable types
• 90º, 120°, or 180º plug and receptacle connectors
• Solid tinned copper cable
Category 2, 3, and 5
2
www.adc.com • +1-952-938-8080
12/00 • 218
Connectorized Cables
Connectorized Cables
Unshielded Cables
Unshielded cables are manufactured of solid tinned copper covered with PVC insulation.
Shielded Plenum Cables
Shielded plenum cables are manufactured of solid tinned copper with PVC insulation. Shielded plenum
cables include an aluminum foil/mylar shielding ground wire.
Low Smoke Zero Halogen (LSZH) Cables
Primarily specified in Europe per European Telecommunications Standards Institute (ETSI) guidelines,
LSZH cables comply with building codes requiring low smoke emission standards.
Shielded Cables
Shielded cables are manufactured of solid tinned copper, covered with PVC insulation. Shielded cables
include an aluminum polyester shielding ground wire.
12/00 • 218
Connectorized Cables
3
www.adc.com • +1-952-938-8080
Category 2 and 3 Cables
With Standard Connectors
Catalog Number
___ ___ - ___ ___ ___ ___ ___ ___ - ___ ___ ___
U
S
P
Unshielded
Shielded*
Shielded Plenum
P
R
S
Plug
Receptacle
Stub
2
3
Category 2
Category 3
First Connector Type
P
R
Plug
Receptacle
First Connector Angle
A
B
C
90º
120º
180º
Cable Type
Second Connector Type
Second Connector Angle
A
B
C
X
90º
120º
180º
Stub
Length in Feet
1' increments up to 20'
5' increments from 20' to 100'
50' increments thereafter
Note: 1 foot = 30.48 cm
XXX
25
32
25 Pairs
32 Pairs
*Shielded cable does not come
with metal shell connectors.
Number of
Cable Pairs
Features and Benefits
• Category 2 cable can transmit data at speeds up to 4 Mbps
• Category 3 cable is designed for 10BaseT networks and can transmit data at speeds up to 10 Mbps
• Standard cables feature a plug or receptacle on one end with a plug, receptacle, or stub on the opposite end.
Connectors are available in 90º, 120º, or 180º angles.
12/00 • 218
Connectorized Cables
4
www.adc.com • +1-952-938-8080
Category 5 Cables
With Standard Connectors
U
S
Unshielded
Shielded*
5 Category 5**
First Connector Type
P
R
Plug
Receptacle
First Connector Angle
25
32
25 Pairs
32 Pairs
Cable Type
Second Connector Angle
*Shielded cable does not come
with metal shell connectors.
A
B
C
X
90º
120º
180º
Stub
Length in Feet
1' increments up to 20'
5' increments from 20' to 100'
50' increments thereafter
Note: 1 foot = 30.48 cm
XXX
Catalog Number
___ ___ - ___ ___ ___ ___ ___ ___-___ ___ ___
A
B
C
90º
120º
180º
Number of
Cable Pairs
P
R
S
Plug
Receptacle
Stub
Second Connector Type
** ADC’s Category 5 cable assemblies are designed to complement standard DSLAM wiring schemes.
Though the Category 5 cable assemblies are manufactured using Category 5 cable and connectors,
the final cable assembly is not Category 5 tested.
Features and Benefits
• Category 5 cable can transmit data at speeds up to 100 Mbps
• Ideal for DSL applications
• Standard cables feature a plug or receptacle on one end with a plug, receptacle, or stub on the opposite end.
Connectors are available in 90º, 120º, or 180º angles.
12/00 • 218
Connectorized Cables
These specialty cables feature a plug or receptacle on one end with a combination of two plugs, receptacles,
or stubs on the opposite end. Commonly known as “Y-cables,” these cables support the interface
between high and lower cable count equipment elements. Other types of specialty cables (e.g. dual-sided
connectors) are available upon request.
Specialty Y-Cable
5
www.adc.com • +1-952-938-8080
Catalog Number
___ ___ - ___ ___ ___ ___ ___ ___ - ___ ___ ___- ___ ___
U
S
Unshielded
Shielded*
Length in Feet
1' increments up to 20'
5' increments from 20' to 100'
50' increments thereafter
Note: 1 foot = 30.48 cm.
XXX
2
3
Category 2
Category 3
First Connector Type
P
R
Plug
Receptacle
First Connector Angle
A
B
C
90º
120º
180º
Cable Type
Second Connector Angle
A
B
C
X
90º
120º
180º
Stub
The cable is configured to
correspond to specific
equipment wiring schemes.
Contact ADC for details.
XX
25
32
25 Pairs
32 Pairs
Number of
Cable Pairs
W
X
Y
Z
Receptacle/Receptacle
Stub/Stub
Plug/Plug
Plug/Receptacle
Second Connector Types
** ADC’s Category 5 cable assemblies are designed to complement standard DSLAM wiring schemes.
Though the Category 5 cable assemblies are manufactured using Category 5 cable and connectors,
the final cable assembly is not Category 5 tested.
5 Category 5**
Equipment
Wiring Scheme
*Shielded cable does not come
with metal shell connectors.
Specialty Cables
With Y-Cables
12/00 • 218
Connectorized Cables
6
www.adc.com • +1-952-938-8080
Specialty Cables
Low Smoke Zero Halogen (LSZH) Cables
Custom Connectors
ADC can create custom connectorized cables to meet unique connectivity needs. For information regarding
specialty dual-sided connectors and other customized cables, contact ADC.
Primarily specified in Europe per European Telecommunications Standards Institute (ETSI) guidelines, LSZH
cables comply with building codes requiring low smoke emission standards.
Specialty Dual-Sided Connector
Catalog Number
___ ___ - ___ ___ ___ ___ ___ ___ - ___ ___ ___
L LSZH
P
R
S
Plug
Receptacle
Stub
3
5
Category 3
Category 5
First Connector Type
P
R
Plug
Receptacle
First Connector Angle
A
B
C
90º
120º
180º
Cable Type
Second Connector Type
Second Connector Angle
A
B
C
X
90º
120º
180º
Stub
Length in Feet
1' increments up to 20'
5' increments from 20' to 100 '
50' increments thereafter
Note: 1 foot = 30.48 cm
XXX
25
32
25 Pairs
32 Pairs
Number of
Cable Pairs
L
Loss (dB)
Crosstalk
300 kHz -10 MHz
12345678910
Frequency (MHz)
-40
0
-140
-120
-100
-80
-60
-20
Pair 1 / Pair 2
Pair 1 / Pair 3
Pair 1 / Pair 4
Pair 1 / Pair 5
Pair 1 / Pair 6
Pair 1 / Pair 7
Pair 1 / Pair 8
Pair 1 / Pair 9
Pair 1 / Pair 10
Pair 1 / Pair 11
Pair 1 / Pair 12
Pair 1 / Pair 13
Pair 1 / Pair 14
Pair 1 / Pair 15
Pair 1 / Pair 16
Pair 1 / Pair 17
Pair 1 / Pair 18
Pair 1 / Pair 19
Pair 1 / Pair 20
Pair 1 / Pair 21
Pair 1 / Pair 22
Pair 1 / Pair 23
Pair 1 / Pair 24
Pair 1 / Pair 25
12/00 • 218
Connectorized Cables
7
www.adc.com • +1-952-938-8080
Connectorized Cables
Specifications
Unshielded, 25 Pair Cable
24 AWG (0.5 mm)
Solid tinned copper
30 micro-inches of tin, minimum
PVC, 0.006" thickness
PVC, 0.030" thickness
0.37"
Cable meets the requirements of Underwriters Laboratories,
Standard 1581, vertical tray flame test (CM Rating).
500 Vrms per MIL-STD-202, method 301
1.0 Amps per conductor
300 Volts
0º C to 40º C
95% per MIL-STD-202, Method 106
MECHANICAL
Conductors
Type:
Material:
Plating:
Insulation:
Jacket
Material:
Outer Diameter:
FLAMMABILITY:
ELECTRICAL
Dielectric Withstanding Voltage:
Current Rating:
Voltage Rating:
ENVIRONMENTAL
Operating Temperature:
Moisture Resistance:
Note: These are representative specifications for unshielded, 25 pair Category 2 cable. Complete specifications for all products are
available upon request.
Unshielded, 25 Pair Cable
with 90º Connector
Return Loss
300 kHz - 10 MHz
-80
-70
-60
-50
-40
-30
-20
-10
0
12345678910
Frequency (MHz)
Loss (dB)
Pair 1
Pair 2
Pair 3
Pair 4
Pair 5
Pair 6
Pair 7
Pair 8
Pair 9
Pair 10
Pair 11
Pair 12
Pair 13
Pair 14
Pair 15
Pair 16
Pair 17
Pair 18
Pair 19
Pair 20
Pair 21
Pair 22
Pair 23
Pair 24
Pair 25
12/00 • 218
Connectorized Cables
8
www.adc.com • +1-952-938-8080
Connectorized Cables
Specifications
Shielded, 25 Pair Cable
24 AWG (0.5 mm)
Solid tinned copper
PVC, 0.032" thickness
Aluminum polyester with 25% minimum overlap. 0.001" thickness
One 24 AWG (0.5 mm), solid tinned copper
PVC, 0.022" thickness
0.33"
Cable meets the requirements of Underwriters Laboratories,
Standard 1581, vertical tray flame test (CM Rating).
500 Vrms per MIL-STD-202, method 301
1.0 Amps per conductor
300 Volts
0º C to 40º C
95% per MIL-STD-202, Method 106
MECHANICAL
Conductors
Type:
Material:
Insulation:
Shield:
Drain:
Jacket
Material:
Outer Diameter:
FLAMMABILITY:
ELECTRICAL
Dielectric Withstanding Voltage:
Current Rating:
Voltage Rating:
ENVIRONMENTAL
Operating Temperature:
Moisture Resistance:
Note: These are representative specifications for shielded, 25 pair Category 2 cable. Complete specifications for all products are
available upon request.
Shielded, 25 Pair Cable
with 90º Connector
Return Loss
300 kHz -10 MHz
1 2 3 4 5 6 7 8 9 10
Frequency (MHz)
Loss (dB)
Pair 1
Pair 2
Pair 3
Pair 4
Pair 5
Pair 6
Pair 7
Pair 8
Pair 9
Pair 10
Pair 11
Pair 12
Pair 13
Pair 14
Pair 15
Pair 16
Pair 17
Pair 18
Pair 19
Pair 20
Pair 21
Pair 22
Pair 23
Pair 24
Pair 25
0
-80
-70
-60
-50
-40
-30
-20
-10
0
1 2 3 4 5 6 7 8 9 10
Loss (dB)
Crosstalk
300 kHz - 10 MHz
-80
-60
-20
-40
-70
-50
-10
-30
Frequency (MHz)
Pair 1 / Pair 2
Pair 1 / Pair 3
Pair 1 / Pair 4
Pair 1 / Pair 5
Pair 1 / Pair 6
Pair 1 / Pair 7
Pair 1 / Pair 8
Pair 1 / Pair 9
Pair 1 / Pair 10
Pair 1 / Pair 11
Pair 1 / Pair 12
Pair 1 / Pair 13
Pair 1 / Pair 14
Pair 1 / Pair 15
Pair 1 / Pair 16
Pair 1 / Pair 17
Pair 1 / Pair 18
Pair 1 / Pair 19
Pair 1 / Pair 20
Pair 1 / Pair 21
Pair 1 / Pair 22
Pair 1 / Pair 23
Pair 1 / Pair 24
Pair 1 / Pair 25
12/00 • 218
Connectorized Cables
9
www.adc.com • +1-952-938-8080
Unshielded, 32 Pair Cable
24 AWG (0.5 mm)
Solid tinned copper
PVC, 0.006" thickness
PVC, 0.035" thickness
0.43"
Cable meets the requirements of Underwriters Laboratories,
Standard 1581, vertical tray flame test (CM Rating).
750 Vrms per MIL-STD-202, method 301
1.0 Amps per conductor
150 Volts
-30º C to +60º C
95% per MIL-STD-202, Method 106
MECHANICAL
Conductors
Type:
Material:
Insulation:
Jacket
Material:
Outer diameter:
FLAMMABILITY:
ELECTRICAL
Dielectric Withstanding Voltage:
Current Rating:
Voltage Rating:
ENVIRONMENTAL
Operating Temperature:
Moisture Resistance:
Note: These are representative specifications for unshielded, 32 pair Category 2 cable. Complete specifications for all products are
available upon request.
Unshielded, 32 Pair Cable
with 90º Connector
Connectorized Cables
Specifications
Loss (dB)
Return Loss
300 kHz - 10 MHz
Frequency (MHz)
1 2 3 4 5 6 7 8 9 10
-80
-70
-60
-50
-40
-30
-20
-10
0
Pair 1
Pair 2
Pair 3
Pair 4
Pair 5
Pair 6
Pair 7
Pair 8
Pair 9
Pair 10
Pair 11
Pair 12
Pair 13
Pair 14
Pair 15
Pair 16
Pair 17
Pair 18
Pair 19
Pair 20
Pair 21
Pair 22
Pair 23
Pair 24
Pair 25
Crosstalk
300 kHz - 10 MHz
Frequency (MHz)
1 2 3 4 5 6 7 8 9 10
-40
0
-140
-120
-100
-80
-60
-20
Pair 1 / Pair 2
Pair 1 / Pair 3
Pair 1 / Pair 4
Pair 1 / Pair 5
Pair 1 / Pair 6
Pair 1 / Pair 7
Pair 1 / Pair 8
Pair 1 / Pair 9
Pair 1 / Pair 10
Pair 1 / Pair 11
Pair 1 / Pair 12
Pair 1 / Pair 13
Pair 1 / Pair 14
Pair 1 / Pair 15
Pair 1 / Pair 16
Pair 1 / Pair 17
Pair 1 / Pair 18
Pair 1 / Pair 19
Pair 1 / Pair 20
Pair 1 / Pair 21
Pair 1 / Pair 22
Pair 1 / Pair 23
Pair 1 / Pair 24
Pair 1 / Pair 25
12/00 • 218
Connectorized Cables
10
www.adc.com • +1-952-938-8080
Shielded, 32 Pair Cable
24 AWG (0.5 mm)
Solid tinned copper
PVC, 0.006" thickness
Aluminum polyester with 25% minimum overlap. 0.001" thickness
One 24 AWG (0.5 mm), solid tinned copper
PVC, 0.035" thickness
0.40"
Cable meets the requirements of Underwriters Laboratories,
Standard 1581, vertical tray flame test (CM Rating).
2500 Vrms per MIL-STD-202, method 301
1.0 Amps per conductor
300 Volts
0º C to 60º C
95% per MIL-STD-202, Method 106
MECHANICAL
Conductors
Type:
Material:
Insulation:
Shield:
Drain:
Jacket
Material:
Outer diameter:
FLAMMABILITY:
ELECTRICAL
Dielectric Withstanding Voltage:
Current Rating:
Voltage Rating:
ENVIRONMENTAL
Operating Temperature:
Moisture Resistance:
Note: These are representative specifications for unshielded, 32 pair Category 2 cable. Complete specifications for all products
are available upon request.
Shielded, 32 Pair Cable
with 90º Connector
Connectorized Cables
Specifications
Return Loss
300 kHz - 10 MHz
-80
-70
-60
-50
-40
-30
-20
-10
0
1 2 3 4 5 6 7 8 9 10
Frequency (MHz)
Loss (dB)
Pair 1
Pair 2
Pair 3
Pair 4
Pair 5
Pair 6
Pair 7
Pair 8
Pair 9
Pair 10
Pair 11
Pair 12
Pair 13
Pair 14
Pair 15
Pair 16
Pair 17
Pair 18
Pair 19
Pair 20
Pair 21
Pair 22
Pair 23
Pair 24
Pair 25
Loss (dB)
Crosstalk
300 kHz -10 MHz
Frequency (MHz)
1 2 3 4 5 6 7 8 9 10
-40
0
-140
-120
-100
-80
-60
-20
Pair 1 / Pair 2
Pair 1 / Pair 3
Pair 1 / Pair 4
Pair 1 / Pair 5
Pair 1 / Pair 6
Pair 1 / Pair 7
Pair 1 / Pair 8
Pair 1 / Pair 9
Pair 1 / Pair 10
Pair 1 / Pair 11
Pair 1 / Pair 12
Pair 1 / Pair 13
Pair 1 / Pair 14
Pair 1 / Pair 15
Pair 1 / Pair 16
Pair 1 / Pair 17
Pair 1 / Pair 18
Pair 1 / Pair 19
Pair 1 / Pair 20
Pair 1 / Pair 21
Pair 1 / Pair 22
Pair 1 / Pair 23
Pair 1 / Pair 24
Pair 1 / Pair 25
12/00 • 218
Connectorized Cables
11
www.adc.com • +1-952-938-8080
Connectorized Cables
Specifications
Shielded Plenum, 32 Pair Cable
24 AWG (0.5 mm)
Solid tinned copper
Low smoke PVC, 0.006" thickness
Overall aluminum foil/mylar providing full coverage
One 24 AWG (0.5 mm), solid tinned copper
Low smoke PVC, 0.016" thickness
0.362"
Cable meets the requirements of Underwriters Laboratories,
Standard 1581, vertical tray flame test (CM Rating).
2500 Vrms per MIL-STD-202, method 301
1.0 Amps per conductor
300 Volts
0º C to 60º C
95% per MIL-STD-202, Method 106
MECHANICAL
Conductors
Type:
Material:
Insulation:
Shield:
Drain:
Jacket:
Material:
Outer diameter:
FLAMMABILITY:
ELECTRICAL
Dielectric Withstanding Voltage:
Current Rating:
Voltage Rating:
ENVIRONMENTAL
Operating Temperature:
Moisture Resistance:
Note: These are representative specifications for shielded, 32 pair Category 2 cable. Complete specifications for all products are
available upon request.
Shielded Plenum, 32 Pair Cable
with 90º Connector
Return Loss
300 kHz - 10 MHz
-80
-70
-60
-50
-40
-30
-20
-10
0
1 2 3 4 5 6 7 8 9 10
Frequency (MHz)
Loss (dB)
Pair 1
Pair 2
Pair 3
Pair 4
Pair 5
Pair 6
Pair 7
Pair 8
Pair 9
Pair 10
Pair 11
Pair 12
Pair 13
Pair 14
Pair 15
Pair 16
Pair 17
Pair 18
Pair 19
Pair 20
Pair 21
Pair 22
Pair 23
Pair 24
Pair 25
-40
0
1
2 3
4 5 6 7 8 9 10
Pair 1 / Pair 2
Pair 1 / Pair 3
Pair 1 / Pair 4
Pair 1 / Pair 5
Pair 1 / Pair 6
Pair 1 / Pair 7
Pair 1 / Pair 8
Pair 1 / Pair 9
Pair 1 / Pair 10
Pair 1 / Pair 11
Pair 1 / Pair 12
Pair 1 / Pair 13
Pair 1 / Pair 14
Pair 1 / Pair 15
Pair 1 / Pair 16
Pair 1 / Pair 17
Pair 1 / Pair 18
Pair 1 / Pair 19
Pair 1 / Pair 20
Pair 1 / Pair 21
Pair 1 / Pair 22
Pair 1 / Pair 23
Pair 1 / Pair 24
Pair 1 / Pair 25
Loss (dB)
Crosstalk
300 kHz - 10 MHz
-140
-120
-100
-80
-60
-20
Frequency (MHz)

Không có nhận xét nào: